Herunterladen Diese Seite drucken

Valpes VT1500 Installations- Und Bedienungsanleitung Seite 13

Actionneur électrique

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
DESCRIPTION
These electric actuators have been designed to perform the control of a valve with 90° rotation. Please consult us for any
different application. We cannot be held responsible if the mentioned actuators are used for any other purpose.
TRANSPORT AND STORAGE
 The forwarding agents being held as responsible for damages and delays of the delivered goods, the consignees are
obliged to express if applicable their reserves, prior to accept the goods. The goods delivered directly ex works are sub-
ject to the same conditions.
 The transport to the place of destination is carried out by using rigid packing material.
 The products must be stored in clean, dry, and ventilated places, preferably on appropriate palettes or shelves. Actua-
tors should not be stored upside down.
MAINTENANCE
 Maintenance is ensured by our factory. If the supplied product does not work, please check the wiring according to the
electric diagram as well as the power supply of the electric actuator in question.
 For any question, please contact our after-sales service.
 To clean the outside of the actuator, use a lint and soapy water. DO NOT USE ANY CLEANING PRODUCT WITH SOL-
VENT OR ALCOHOL.
WARRANTY
 Our products are thoroughly tested and set in factory.
 These products are 3-year warranty from the manufacturing site delivery date or 50,000 actuations against all types of
manufacturing and material faults (operating time and model class according to standard CEI34).
 The said guarantee covers solely replacement or – at our full sole discretion - repair, free of charge, of those components
of the goods supplied which in our sole view present proven manufacturing defects.
 This warranty excludes any damage due to normal product usage or friction and does not include any modified or unau-
thorized repair for which we will not accept any request for damage (either direct or indirect) compensation (for full details
see our website).
 The guarantee does not cover the consequences of breakdown and excludes any payments for indemnities. The acces-
sories, consumables (batteries...) and adaptations are excluded from the guarantee. In the case where a customer has
not proceeded to payments within the agreed period, our guarantee will be suspended until the delayed payments have
been received and with the consequence that this suspension will not prolong the guarantee period in any case.
 All sales subject to our terms to be found on our website.
RETURN OF GOODS
 When the actuator receives his actuator, he must check its conformity according to its definition.
 The acceptance of the goods by the purchaser disclaims the supplier of all responsibility if the purchaser discovers any
non-conformity after the date of acceptance. In such case, the repair cost will be borne by the purchaser who will also
exclusively bear all financial consequences of any resulting damages. Returned goods will only be accepted if our prior
agreement has been given to this procedure : the goods must be sent free of all cost and being shipped solely and in
their original packing. The returned goods will be credited to the purchaser with a reduction of 40% on the unit's price
charged in accordance with the original invoice of the returned goods.
SAFETY INSTRUCTIONS
 Any intervention must only be carried out by a qualified electrician or other person instructed in accordance with the reg-
ulations of electric engineering, safety, and all other applicable directives.
 Strictly observe the wiring and set-up instructions as described in the manual: otherwise, the proper working of the actu-
ator can not be guaranteed anymore. Verify that the indications given on the identification label of the actuator fully corre-
spond to the characteristics of the electric supply.
MOUNTING INSTRUCTIONS
 Do not mount the actuator less than 30 cm from an electromagnetic disturbance source.
 Do not mount the actuator « upside down ».
 Do not position the equipment so that it is difficult to operate the disconnecting device.
 Respect all safety rules during fitting, dismantling and porting of this apparatus.
DSBA3004 • Rév. 12/06/2023
UK
(To be read prior to the installation of the product
(To be read prior to the installation of the product
)
)
13

Werbung

loading

Diese Anleitung auch für:

Vt2400