ThermoCamera HighSense (Pro) UPDATE
Warm-up time
This thermal imaging camera is a precision device which can identify extremely small temperature
differentials using highly sensitive infrared sensors. For applications where extremely accurate temperature
readings for the measurement results are required, the thermal imaging camera must be operational
for at least ten minutes every time either it is switched on or the temperature range is changed in order
to adjust the integral sensors to their operating temperature. Rapidly changing device or ambient
temperatures, air flows, or external temperature sources are to be avoided.
Updated CustomApps
Most CustomApps have been updated with respect to existing operating instructions. The following
explanations replace sections 16.2 to 16.8 in the operating instructions.
16.2
CustomApps: ThermalInsulation-Control
16.3
CustomApps: FloorHeating-Control
ThermalInsulation-Control is suitable for checking
thermal insulation and analysing energy losses in
indoor spaces. Cold building surfaces which can lead
to energy losses are shown as blue to black, mid-warm
surfaces in green to yellow, and warm surfaces in red
to white. The horizontal line makes it easier to identify
slight insulation problems and provides an overview of
the energy efficiency of the area of the building under
investigation. Typical weak spots are usually located
on building façades but can also be around external
doors, windowsills, pipework, and in heated cellars.
FloorHeating-Control provides visualisation of
cable routing, thermal distribution and possible air
inclusions. It allows you to check that an existing
or recently installed underfloor heating system is
heating up evenly. The thermal imaging camera
provides information on the floor surface temperature
which is also an important indicator of the heating
system's efficiency.