Herunterladen Diese Seite drucken

Balluff BOS 50K RH12-S4 Serie Kurzanleitung Seite 5

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Photoelectric Sensors
Red light diffuse reflective with background supression BOS 50K-...-RH12-S4
No. 862 739 EN • F18
Order Code Diffuse reflective with background supression
BOS0156
BOS018T
BOS018N
BOS018P
BOS018R
BOS018U
Safety Notes
Safety Notes
These photoelectric sensors may not be used in
applications where personal safety depends on
proper function of the devices (not safety
designed per EU machine guideline). Read these
operating instructions carefully before putting the
device into service.
Exempt Group according to IEC 62471.
DO NOT STARE INTO THE LIGHT BEAM!
Danger of glare and irritation!
The sensor must be installed so that no direct
looking into the light source is possible even
during operation.
The CE Mark verifies that our products meet the
requirements of the current EMC Directive.
In our EMC Laboratory, which is accredited by the
DATech for Testing of Electromagnetic Compatibility,
proof has been documented that these Balluff products
meet the EMC requirements of the harmonized standard
EN 60947-5-2.
Display- and Operating Elements
green LED: Power on Indicator/short circuit indicator
yellow LED: Output signal indicator/Error indicator
10-turn potentiometer for precise setting of the
switching distance
Fig. 1: Display- and Operating Elements
operating elements
The green LED Power on/short circuit indicator
LED on: The sensor is operating
LED flashes: Short circuit on the output
LED off: Sensor not ready
The yellow LED Output signal/Error indicator
LED on: Light at the receiver
LED flashes: Insufficient light at the receiver
LED off: No light at the receiver
10-turn potentiometer without stop
Used for setting the switching distance.
5
BOS 50K-PSV-RH12-S4
BOS 50K-NSV-RH12-S4
BOS 50K-PS-RH12-S4
BOS 50K-PA-RH12-S4
BOS 50K-NA-RH12-S4
BOS 50K-POV-RH12-S4
Installation
Installation
Attention! Do not look into the lightbeam.
a = Optical axis of receiver
b = Optical axis of emitter
Fig. 2: Dimensions
Setting
To increase the switching distance: Turn potentiometer
clockwise.
To reduce switching distance: Turn potentiometer
counter-clockwise.
1. Position the sensor at the desired distance to the
object.
2. Set the potentiometer so that the object is reliably
Display- and
detected: The yellow LED will be on toindicate light is
being received.
3. Remove the object. The background should not be
detected: The yellow LED should not be on.
PNP
N.O.
NPN
N.O.
PNP
N.O.
PNP
N.O.+ N.C.
NPN
N.O.+ N.C.
PNP
N.C.
5.5
a
3
b
18.5
Error output
Error output
-
-
-
Error output
a
60.2
b
7.5