Herunterladen Diese Seite drucken

Grohe Blue Mono Pure 31 301 Bedienungsanleitung Seite 7

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
The control unit of the GROHE Blue
with the 600 liter filter cartridge at the factory.
For operation with other filter cartridges the control unit must be
set out.
Setting filter size, see fold-out page II, Fig. [7].
button for filter size selection:
• Press and hold
button once until the currently setted
value (e. g. F1) flashes in the display
• Press the
button and select the required value appears
- F4:
600 liters
40 404 001
- F5:
1,500 liters
40 430 001
- F6:
3,000 liters
40 412 001
- F7:
600 liters
40 691 001 (Magnesium)
- F8:
3.000 liters
40 547 001 (Activ carbon)
• Press and hold the
button until the required value stops
flashing
• Release the
button:
The remaining filter capacity is displayed.
The fitting is now fully installed and ready for operation.
Note: The various filter cartridges can be ordered at
www.grohe.com.
Maintenance
Resetting filter capacity after changing filter cartridge, see
fold-out page II, Fig. [7].
button for filter replacement reset:
• Press and hold
button until rF flashes in the display.
• Release the
button and press again until rF stops
flashing.
• Release the
button.
The remaining filter capacity is reset and then displayed
again.
Fault
Cause
Filtered water not
• Water supply interrupted
flowing
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
No filtered water,
• Fitting and control unit not synchronized
®
Blue
handle flashes
red, E4 in the display
No filtered water,
• Values range does not concur
®
Blue
handle flashes
red, E6 in the display
E7, E8 in the display
• Filter capacity exceeded
Indicator lamps
• Control not recognised
do not flash/flash
continuously
®
fitting is set for operation
Always disconnect the power supply before performing
maintenance work on the system. The plug-in connectors
can then be disconnected, see fold-out page II, Fig. [7].
Inspect and clean all components and replace if necessary.
I. Mousseur (13 199), see fold-out page I.
Assemble in reverse order.
II. Solenoid valve (42 390), see fold-out page I.
Assemble in reverse order.
Service
Note the Fault / Cause / Remedy table for information on
eliminating problems.
If EE flashes or the problem cannot be rectified, interrupt the
power supply and consult a specialist installer or contact the
GROHE Service Hotline via email under TechnicalSupport-
HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Environment and recycling
Used filter cartridges can be disposed of hazard-free in
domestic waste.
Warning
Risk of damage:
Remedy
- Open shut-off valves
- Replace solenoid valve
- Attach plug-in connector
- Synchronise with one another, see section
Installation
- Synchronise with one another, see section
Installation
- Change filter cartridge immediately
- With mains plug connected, disconnect plug-in
connector, wait 30 seconds and reconnect
4

Werbung

loading