Herunterladen Diese Seite drucken

Grohe Blue Mono Pure 31 301 Bedienungsanleitung Seite 6

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
GB
GB
Safety notes
Avoid danger due to damaged power cords. In the
case of damage, the control unit must be replaced by
the manufacturer or his customer service department
or an equally qualified person.
• The control unit and plug must not be directly or indirectly
sprayed with water when cleaning.
• The control unit must be connected to a permanent power
supply.
• Installation of the fitting with filter cartridge is only permitted
in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
Electrical data:
• Voltage supply:
• Power consumption:
• Standby power loss:
• Type of protection
– Control unit:
– Mains plug:
Sanitary data:
• Operating pressure:
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
• Flow rate at 0.3 MPa flow pressure:
• Ambient temperature:
• Adjustable bypass, factory setting:
• Filter capacity at bypass setting 2
(Carbonate hardness 10 - 24 °KH):
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
3
100 - 240 V AC / 50/60 Hz
9 W
< 1.0 W
IP 68
IP 40
0.2 – 0.8 MPa
approx. 3.5 l/min
4 – 32 °C
2
max. 750 liters
corresponds to max. 12 months
A
2
2,500 V
100 °C
Electrical installation
Electrical installation work must only be performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 60364-7-701 (corresponding
to VDE 0100 Part 701) as well as all national and
local regulations.
Installation
Refer to the dimensional drawing on fold-out page I.
Flush pipes thoroughly before and after installation
(observe EN 806)!
Install solenoid valve on service valve, see fold-out page II,
Figs. [1a] or [1b].
Install fitting, see Figs. [2] and [3].
Install control unit, see Fig. [4].
Important: Do not connect voltage supply yet.
Connect fitting, see Figs. [2], [5] and [6].
Open hot and cold water supply and check that
connections are watertight.
Connect voltage supply via mains plug, see Fig. [7].
The display illuminates and the remaining filter capacity is
displayed in percent.
Operation / Commissioning
®
Open Blue
handle to draw off filtered GROHE Blue
see fold-out page II, Fig. [8].
Control unit, see fold-out page II, Fig. [7].
The buttons perform the following functions:
Filter replacement reset
Filter size selection
Carbonate hardness adjustment
Display, see fold-out page II, Fig. [7].
In the inactive state, the remaining filter capacity is displayed
in percent.
Set carbonate hardness at filter head, see Fig. [9].
The relevant water supplier can provide information on the
carbonate hardness.
Set carbonate hardness at bypass setting of filter head to local
conditions, see table column A on fold-out page III.
Setting carbonate hardness on control unit, see table
column B on fold-out page III and Fig. [7].
button for carbonate hardness adjustment:
• Press and hold the
button once until the currently setted
value (e. g. C3) flashes in the display
• Press the
button and select the required value:
- C4: carbonate hardness
- Factory setting:
C3: carbonate hardness
- C2: carbonate hardness
- C1: carbonate hardness
• Press and hold the
button until the setted value stops
flashing
• Release the
button.
The remaining filter capacity is displayed.
The liter capacity of the cartridge varies according to the water
hardness set and the size of the cartridge, see table on fold-
out page III.
®
water,
9
(bypass 3)
10 - 24
(bypass 2)
25 - 29
(bypass1)
30
(bypass 0)

Werbung

loading