Herunterladen Diese Seite drucken

Bauknecht CTAR 6360 IN/1 Gebrauchs- Und Installationsanleitung Seite 12

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

150 mm
min
ELECTRICAL CONNECTION
Electrical connection must be made before
connecting the appliance to the electricity supply.
Installation must be carried out by qualified
personnel who know the current safety and
installation regulations. Specifically, installation must
be carried out in compliance with the regulations of
the local electricity supply company.
Make sure the voltage specified on the dataplate
located on the bottom of the appliance is the same as
that of the home.
Regulations require that the appliance be earthed:
use conductors (including the earth conductor) of the
appropriate size only.
The manufacturer declines all liability for injury to
persons or animals and for damage to property
resulting from failure to observe the regulations
provided in this chapter.
12
150 mm
min
55 mm
min
600 mm
CONNECTION TO THE TERMINAL BLOCK
For the electrical connection, use an H05RR-F cable
as specified in the table below.
The appliance must be connected to the electricity
supply by means of an all-pole disconnect switch
with minimum contact gap of 3 mm.
L
N
230V
Attention: the power supply cable must be long enough to
allow the cooktop to be removed from the worktop and must
be positioned so as to avoid damage or overheating caused
by contact with the base.
H05RR-F3x1.5
PE
H05RN-F3x1.5
20 mm
min

Werbung

loading