X1
In 4
In 3
S3
0
1
S1
S2
Out 4
Out 3
S
B
NO C
NC
NO C
Terminal connections I/O-Modul DCW
X2
3
DCW
B
ext.
A
1
X3
3
DCW
B
ext.
A
1
X4
In 1
X5
In 2
X6
In 3
X7
In 4
X8
NC
Out 1
C
NO
X9
NC
Out 2
C
NO
X10
NC
Out 3
C
NO
X11
NC
Out 4
C
NO
Description I/O-Modul DCW
X1
Connection to the firmware programming system
S1
Housing anti-tamper / anti-sabotage contact
S2
B = Operation (Housing anti-tamper contact activated);
S = Service (Housing anti-tamper contact deactivated)
S3
Micro-switches for setting the device address:
Switch
Address
ON
1
2
0
0
1
0
0
1
1
1
DORMA GmbH + Co. KG
www.dorma.com
RZ-TMS 24V
In 2
In 1
X2
X3
Out 2
Out 1
NC
NO C
NC
NO C
NC
ON
Address 1
Tableau function
GND
+24 v DC
Short-time unlocking*
Long-time unlocking*
Permanent unlocking*
lock*
Pre-alarm
(door open)*
Main alarm
(door open)*
Emergency push
button depressed*
locked*
1
2
3
4
DORMA Platz 1
D-58256 Ennepetal
Technical data:
Power supply:
Current input:
Switch output:
ON
Address 2
Address 3
General function
Interlock control
function
fire hazard alert
Access control 1,
system*
door 1*
free programable
Disable input*
free programable
Opposite station
(door 2) unlocked*
free programable
Short-time unlocking*
Permanent unlocking
free programable
activated*
free programable
free programable
free programable
TV locked / unlocked*
free programable
free programable
Tel. +49 2333 793-0
24 v DC, +/- 10%
stabilised
approx. 50 mA
24 v / 1 A
(30 W / 62,5 VA max.)
ON
ON
Address 4
SVP /
Automatic function
SVP lever handle*
SVP locked*
SVP unlocked*
Radar detector*
Activation SVP*
Door contact*
ED Impuls if SVP
is unlocked*
ED Radar if TMS is
longtime or permanent
deaktivated*
* or free programable