Figure 9: Chemical Inlet Manifolds for Chemical Pump Systems. See
These are examples. Your machine can look different.
36026V7J
.
CAUTION 26 : Risk of corrosion damage to the machine and the goods—
• Connect chemical tubes only to chemical manifold inlets.
• Stop leaks. Remove leaked supplies from surfaces.
• Speak to your dealer or Milnor if you see corrosion damage.
Figure 10: Soap Chute and Optional 5-compartment Supply Injector. These are examples. Your
machine can look different.
Soap Chute
1.
Do not let chemical supplies stay on surfaces.
2.
Water pressure regulator. See
3.
Adjustment screw
4.
Water pressure gauge.
5.
Strainer inside
.
CAUTION 27 : Risk of injury and damage—Chemical supplies can splash on personnel
and machine surfaces if water pressure is too high.
• Make sure the pressure is set as told in the maintenance summary.
60044WP2
Supply Injector
Legend
caution statement 27
.
33
Chapter 3. Routine Maintenance
caution statement 26
.
76039CBW
Flush Water Adjustment