Herunterladen Diese Seite drucken

SUEVIA 1000121 Montageanleitung Seite 4

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Fixation on tubes 1½" - 2"
101.0167
Water Connection
½" 102.0175
¾" 102.1039
Water Regulation
102.0634
Water Regulation
Water connection from bottom
3 windlings
4
Fixation
SUEVIA Drinking Bowl Mod. 12P-HK-MS is suited to be fixed on walls as well as on tubes of 1½" - 2".
For installation on tubes (1½"-2") two fixing bracket Ref. 101.0167 are necessary.
4 strong screws are necessary for installation on walls of wood or concrete.
Observe DIN 1988 / DIN EN 1717!
Hole Distance: 2x 76 mm / 1x 120 mm
Installation Height
Recommended installation height from the edge of bowl:
· for horses: 90 - 110 cm / 35,4 - 43,3"
· for calves: 40 - 60 cm / 15,8 - 23,7"
Installation height
Attention!
Flush water line well before you connect the bowl!
Water pressure
Maximum 6 bar / 87 psi water pressure!
Water connection
We recommend as horizontal tube the use of a ¾" pipe. Water connection either from top or bottom is
possible. A union is highly recommended. Water connection however can be done without using a union.
¾"-1"
Fit connection stopper (102.0175 = ½", 102.1039 = ¾") into a free connection piece. Bowl can now be
introduced from the bottom between valve and wall. Screw toghether the valve and the bowl. Use 4 tough
screws for fixing the bowl to the wall. Use large washers!
½" 102.0175
Adjustment of the water quantity
¾" 102.1039
Water quantity can be adjusted by turning the regulating screw (102.0634) to the left:
Slot in vertical position = high water flow
Slot in cross position = low water flow
Attention!
Never turn out regulation screw completely! The water quantity is correctly adjusted, if the bowl is filled
within 14-17 seconds.
Electric connection
Using 24 V there is no danger for the animals.
All installation, maintenance and inspection works must be carried out only by an authorised and qualified
specialist. Local norms must be respected. The assembly instruction of the respective electric devices are
to be followed.
Use in winter season
It is also possible to install the drinkig bowl into a water circuit with a connection set from the bottom
(103.1982 = ½", 103.1983 = ¾").
max min
Junction box
Max. cable lengths
Section e.g.: Type NYY
2,5 mm²
4,0 mm²
6,0 mm²
Guidelines. Please note cable data sheets and local standards
Electrical connection
101.0389
IP54
IP44
230 V
Transformer
24 V
till 100 Watt
till 200 Watt
83 m
132 m
200 m
Not included in the scope of delivery of 12P-HK!
till 300 Watt
till 400 Watt
42 m
28 m
66 m
44 m
100 m
66 m
101.1863
24 V / 30 W
21 m
33 m
50 m

Werbung

loading

Diese Anleitung auch für:

100012412p-hk-ms 1/212p-hk-ms 3/4