Herunterladen Diese Seite drucken

Axor Starck V 12112003 Gebrauchsanleitung, Montageanleitung Seite 2

Werbung

EN
0 2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The product may only be used for bathing, hygienic and body cleaning purposes.
There may be hot water in the glass spout. Risk of scalding.
Dust and other solid particles may deposit in the open spout on or in the water.
Detergents or other harmful liquids may mix with the stagnant water.
The water may go bad due to other external influences.
Because of the open design of the water spout, contamination from outside may
enter the unit.
A damaged glass spout must be replaced. Risk of injury.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The product is only suitable for private use. It is unsuitable for use in semi-public
and public areas.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ Please pay attention to the fact that the mixer is equipped with a laminar spray. This
enhances the natural aspects of water as element of life.
As this laminar spray does not contain any air, we recommend the use of very deep
washbasins to reduce splashing.
For further recommendations please consult the Axor Mixer⁄ Wash Basin Matrix.
To reduce splashing, you can also change the point where the water jet hits the
washbasin. To do so, swivel the spout or loosen the spray former to disable the
vortex. (see page 05 Fig. A - C)
⁄ The drain valve must only be used as intended. It is not allowed to attach other
objects to the drain valve, for example a semi-pedestal.
T E C H N I C A L D A T A
This mixer series-produced with EcoSmart
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
The glass outlet contains lead oxide.
A S S E M B L Y (see page 04)
(flow limiter)
®
max. 1 MPa
0,15 - 0,5 MPa
max. 70°C
max. 70°C ⁄ 4 min
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
D I M E N S I O N S (see page 06)
F L O W D I A G R A M (see page 06)
C L E A N I N G (see page 07)
O P E R A T I O N (see page 10)
⁄ As with all other fittings, do not use the first half liter as drinking water in
the mornings or after standstill of > 4 h. In subtropical and tropical coun-
tries, the first half liter of water must generally be discarded. (For more
information, contact your local environmental or health authorities.)
⁄ After the fitting has been out of use for more than three days (for example
during vacation), discard the residual water from the outlet to prevent
moscitoe breeding.
⁄ When the water is stagnant over a prolonged period of time, dirt particles
from the environment will get into the water. For this reason, the entire
glass spout must be cleaned in regular intervals (at least once per week),
and daily in subtropical and tropical countries.
⁄ The glass spout must be treated with care.
M A I N T E N A N C E (see page 10)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
S P A R E P A R T S (see page 11)
1,6 MPa
S P E C I A L A C C E S S O R I E S (order as an extra)
spray body #92341000 (recommended at operating pressure < 0,15 MPa)
65°C

Werbung

loading