3.3. Calibrationmode
The calibration must be carried out once. It must be carried out at a standstill and with the battery pack inserted. It
is called up automatically on the first start. For e-bikes without a display, there is the option of calibrating using an
alternative method (see point "Performing the calibration for e-bikes without a display"). The calibration consists of
two sections. First a rough calibration, then a fine one. In the first section of the calibration, an increasing speed is
output on the speedometer. Switch off the e-bike as precisely as possible at 10.0
and wait at least 5 seconds.
After switching on again, the fine calibration is carried out. A speed is output on the speedometer, which gradually
approaches 10.0
in small steps and, in the meantime, briefly drops towards 0.0
. As soon as 10.0
is displayed
for the first time (it can take several minutes), switch off the e-bike again and wait at least 5 seconds.
Cancel calibration: If the e-bike is ridden in calibration mode, the calibration is aborted and the sIMPLEk jumps
back to 1:1 mode. In this case, no calibration took place.
Note Stealth Mode:
For the Stealth mode to work correctly, it is necessary for the control panel to allow the
wheel circumference to be changed. The wheel circumference must be set to the standard value (factory setting)
before performing the calibration. After activating the stealth mode, the wheel circumference must be permanently
set to the smallest possible value, otherwise the displayed speeds will not be correct. When calibrating again, the
standard value (factory setting) must first be set again.