Intended use
Only use the product described in this manual as follows:
– Especially designed for dry installation.
• For pumping normal pond water for filter systems, waterfall systems and water course systems.
• While adhering to the technical specifications.
• Adherence to the permissible water quality.
The following restrictions apply to the unit:
• Do not use in swimming ponds.
• Never use the unit with fluids other than water.
• Never run the unit without water.
• Do not use for commercial or industrial purposes.
• Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
• Do not connect to the domestic water supply.
Submersed installation
Attention! Risk of damage! Ensure that the unit does not take in air or run dry.
Cut the stepped hose adapter to suit the hose diameter and screw onto the return. Place the unit horizontally with its
feet downward.
Dry installation
Attention! Risk of damage! Ensure that the unit does not take in air or run dry. Do not connect the unit to the
domestic water lines.
Cut both stepped hose adapters to suit the hose diameters, then screw each adapter onto the intake (front) and return
(top). Place the unit horizontally with its feet at the bottom. To prevent air from being taken in, ensure that unit and sup-
ply hose are always 20 cm below the water level. For optimum operation, OASE recommends using a 1½'' hose, max.
5 m long, on the suction side.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Commissioning/start-up
CAUTION
Risk of injury due to unexpected start-up. Internal monitoring functions may switch off the unit and automatically reacti-
vate it.
Disconnect the power plug before carrying out any work on the unit.
NOTE
Prevent the pump from running dry. Otherwise the pump will be destroyed.
Only operate the pump when it is submerged or flooded.
NOTE
Never connect the pump to a dimmer. Otherwise the pump will be destroyed.
The pump power can only be controlled by an OASE current management unit.
Switching ON/OFF
• Switching on: Plug the power plug into the outlet.
– The unit switches on immediately.
• Switching off: Pull the power plug from the outlet.