Choose the device which is to control the effects. Set the desired Master-mode on the master-device. This
device then works as master-device and controls all other slave-devices, which are to be connected to the
master-device via a DMX cable. Connect the DMX out connectors with the DMX input plug of the next
device.
Set the Slave-mode on every slave-device. Please refer to the instructions under Control Board.
Control Board
The Control Board offers several features: you can simply set the starting address, run the pre-programmed
program or select a DMX channel mode.
Browse through the menu by pressing Menu. Press Enter in order to select the desired menu. You can
change the selection by pressing Up or Down. Press Enter in order to confirm. You can leave every mode by
pressing Menu. The functions provided are listed in the following sections.
Menu
Sub menu
C.000
STAT
W.000
ST.00
DMX
RUN
SLAV
DMX
d001-512
SET
DIM
DMX-controlled operation
You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED SFR-100 COB CW/WW 100W Floor will respond to the controller.
Please, be sure that you don't have any overlapping channels in order to control each LED SFR-100 COB
CW/WW 100W Floor correctly and independently from any other fixture on the DMX-chain.
If several LED SFR-100 COB CW/WW 100W Floor are addressed similarly, they will work synchronically.
If you set, for example, the address to channel 5, the device will use the channels 5 to 8 for control.
Controlling:
After having addressed the LED SFR-100 COB CW/WW 100W Floor, you may now start operating it via your
lighting controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is
data received at the DMX-input, a dot will flash on the display. If there is no data received, the dot will not
flash.
This situation can occur if:
- the XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Description
000-255
Dimmer intensity of LED colors
C = Cold White (CW), W = Warm White(WW)
000-255
Strobe effect 0 – 20 (increasing)
00-20
DMX controlled mode
Slave mode
DMX address setting
Default setting:001
Dimmer speed (step response)
OFF
Off : Response characteristics of LEDs
DIM 1: Response characteristics of halogen lamps,
DIM1
fast
DIM 2: Response characteristics of halogen lamps,
DIM2
middle
DIM 3: Response characteristics of halogen lamps,
DIM3
slow
DIM 4: Response characteristics of halogen lamps,
DIM4
very slow
21/23