DMX-512 connection / connection between fixtures
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Please note, the starting address depends upon which controller is being used.
Only use a DMX-cable and 3-pin XLR-plugs and connectors in order to connect the controller with the fixture
or one fixture with another.
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter-cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated. Plug the terminator with a 120
resistor
between Signal (–) and Signal (+) in the DMX-output of the last fixture.
OPERATION
After you connected the spot to the mains, the LED SFR-100 COB CW/WW 100W Floor starts running.
The display lights up and you can choose the desired mode via the buttons MODE, ENTER, UP, DOWN.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.
Stand-alone mode
In the stand-alone mode, you can do without a controller. Disconnect the EUROLITE LED SFR-100 COB
CW/WW 100W Floor from the controller and call the desired setting. Please refer to the instructions under
Control Board.
Master/Slave-operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear of the LED SFR-100 COB CW/WW 100W Floor you can find an XLR-jack (DMX Out) and an
XLR-plug (DMX In), which can be used for connecting several devices.