Duct-Out Version:
Vapours are evacuated outside through an exhaust pipe attached to the connecting flange.
CAUTION! If the product features one or more carbon filters, they must be removed.
Connect the product to wall-mounted exhaust pipes and holes with a diameter equivalent to the air outlet (connecting
flange).
The use of pipes and outlet holes in the wall with a smaller diameter will reduce the extraction performance and drastically
increase the noise level.
All responsibility in this regard is therefore denied.
• Use a ducting pipe with the shortest length necessary.
• Use a ducting pipe with the least number of bends possible (maximum bend angle: 90°).
• Avoid drastic changes in the ducting pipe diameter.
Recirculating Version:
The suctioned air will be degreased and deodorised before it is sent back into the room. To use the product in this version,
it is necessary to install an additional activated carbon filter system.
ASSEMBLY BEFORE INSTALLATION
• Check that the product is the right size for the installation area.
• Remove the activated carbon filter(s) if supplied (see also relevant paragraph).
• It(they) must be reinstalled if the product is used in the filter version.
• If there are panels and/or walls and/or wall units on the sides, make sure that there is enough space to install the product
and that it is always possible to access the control panel easily.
• The product is equipped with fixing plugs suitable for most walls/ceilings. However, it is necessary to consult a qualified
technician to make sure that the materials are suitable for the type of wall/ceiling. The wall/ceiling must be strong enough
to support the weight of the hood.
ELECTRICAL CONNECTION SAFETY
•The mains voltage must correspond to the voltage indicated on the label found inside the product. •If it features a plug,
connect the product to a socket that complies with current standards, located in an area accessible even after installation.
•If it does not feature a plug (direct connection to the mains) or the plug is not located in an accessible area, even after
installation, apply a standard double pole switch that ensures complete disconnection from the mains in category III
overvoltage conditions, in accordance with the installation rules. • Warning! The power cable must be replaced by the
authorised technical support service or by a person with similar qualifications.
● Please note! Before reconnecting the circuit to the mains power supply, make sure that it is working correctly, always
check that the power cable is correctly installed.
MAINTENANCE WARNINGS
• Cleaning: For cleaning, simply use a cloth moistened with neutral liquid detergents. Do not use cleaning tools or
instruments.
• Avoid the use of abrasive products. DO NOT USE ALCOHOL!
For product maintenance, see the images at the end of the installation marked by this symbol.
Anti-Grease Filter: The metallic anti-grease filter must be cleaned once a month with non-aggressive detergen-
ts, manually or in a dishwasher on a short wash at low temperatures. To remove the anti-grease filter, pull the spring re-
lease handle.
• The Anti-Grease Filter traps the grease particles produced during cooking. When cleaned in the dishwasher, the metal
grease filter may discolour, but its filtering characteristics remain unchanged.
Carbon filter (for filter version only): The cartridge must be replaced at least every four months. It CANNOT
be washed or regenerated. As indicated in the drawings section: remove the anti-grease filters, apply a carbon filter on
each side and attach it to the product. Put the anti-grease filters back in place.
• The carbon filter retains any unpleasant odours produced during cooking. • The saturation of the carbon filter can occur