Verfügbare Sprachen

6
Maintenance
6.1
Storage
Please charge the battery before storing the meter for a longer period of time and store the device
as well as, if applicable, the external sensors and the accessories in the packaging / carrying case
the PCE-DFG N comes with to protect the technical components.
Appendix: load cell (1 ... 100 kN)
7
L [mm]
1 kN
50,8
2,5 ... 5 kN
20,8
10 kN
50,8
20 ... 50 kN
76,2
100 kN
112,78
A [mm]
1 kN
24
2,5 kN
29
5 kN
35
10 kN
39
20 kN ... 50kN
40
100 kN
60
8
Warranty
You can read our warranty terms in our General Business Terms which you can find here:
https://www.pce-instruments.com/english/terms.
H [mm]
W1[mm]
76,2
20,8
76,2
20,8
76,2
27,2
101,6
27,2
177,8
42,93
B [mm]
H [mm]
45
45
53
53
62
63
71
73
72
71
108
109
© PCE Instruments
27
H1 [mm]
15,3
13,6
12,1
20
-
L [mm]
D [mm]
Max
20
M10
0,25 t
22
M12
0,4 t
22
M12
0,7 t
22
M12
30
M20
45
M30
M [mm]
M10 x 1,5
M12 x 1,75
M12 x 1,75
M20 x 1,5
M30 x 2
Weight
110 g
175 g
260 g
1 t
395 g
6 t
450 g
12 t
1700 g

Werbung