Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when
the device is installed in a remote area.
RDM is integrated n the DMX-protocol without influencing the connections. The RDM-data is transmitted via
the standard XLR-poles 1 and 2 – new DMX-cables are not necessary. RDM ready and conventional DMX
devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed
and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
The number and type of RDM parameters depend on the (optional) RDM controller being used.
In order to see or to change the RDM PID code if required, press the MODE button and choose FIXTURE
ID.
Press the ENTER button.
Enter the password 050 via the UP or DOWN button.
You can now see or, if necessary, change the individual RDM PID code of the fixture via the UP or DOWN
button.
Please press the ENTER button again to confirm and to exit this mode.
White Balance
Press the MODE button and choose WHITE BALANCE.
To select the desired color (R, G or B), please press the ENTER button
The brightness (000-255, increasing) can be selected via the UP or DOWN button.
Please press the ENTER button to confirm and to exit the Mode.
Dimmer speed (step response)
Press the MODE button until the display shows DIMMER.
Press the ENTER button.
You can select the dimmer speed: RESPON01 (response characteristics of LEDs) or RESPON02 (response
characteristics of halogen lamps) via the UP or DOWN button.
Confirm your choice by pressing ENTER and to exit the Mode.
Invert function
In this mode, you can change the chaser direction, from left to right or from right to left.
Press the MODE button to select the FLOW INVERT function.
Press the ENTER button. Press the UP or DOWN button to select ON or OFF. This will change the flow
direction.
Please press the ENTER button to confirm and to exit the Mode.
DMX MODE
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED PMB-4 COB RGB 30W NSP Bar will respond to the controller.
Controlling:
After having addressed the LED PMB-4 COB RGB 30W NSP Bar, you may now start operating it via your
lighting controller. Every DMX-channel has a different occupation with different features.
Note: It's necessary to insert the XLR termination plug (with 120
) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.
Attention:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is
no data received at the DMX-input, the display will flash.
This situation can occur if:
- the XLR plug (cable with DMX signal from controller) is not connected with the input of the device.