Overview
Power supply:
230 V AC, 50 Hz ~
Power Out
Fuse: F 2 A, 250 V
3
1
2
1. Fuse
2. Power Out via Neutrik PowerCon socket
3. Power supply via Neutrik PowerCon socket
4. Attachment eyelet
5. Microphone
6. LED display with operating buttons
7. DMX IN, 3-pin
8. DMX OUT, 3-pin
9. DMX IN, 5-pin
10. DMX OUT, 5-pin
INSTALLATION
The LED PMB-4 COB RGB 30W NSP Bar can be installed on the ground or on the wall or ceiling.
Overhead rigging
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
Safety rope
MODE
Microphone
5
4
DANGER TO LIFE!
20/28
1: Ground
DMX IN
2: Signal (-)
3: Signal (+)
DMX OUT
1
2
DMX IN
1: Ground
UP
DOWN
2: Signal (–)
ENTER
3: Signal (+)
4: NC
5: NC