Herunterladen Inhalt Inhalt Diese Seite drucken

Display Symbols; Button Functions; Commissioning; Initial Operation - VOLTCRAFT 12 29 53 Bedienungsanleitung

Farb-analysegerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Display symbols

R
Colour value for red
G
Colour value for green
B
Colour value for blue
Hue
Measuring value for the colour hue
Sat
Measuring value for the colour saturation
Lum
Measuring value for the luminance
Battery replacement symbol; please replace the batteries immediately to avoid measuring errors!
Mesu
Measuring in progress. The sensor may not be moved or lifted.
CAL
RGB calibration in progress. The sensor may not be moved or lifted.
RS232 Interface is active, data transfer in progress.

Button functions

POWER Power switch; to switch the unit on and off
TEST
A push of this button starts measuring. You do not have to keep this button depressed.
Function Function button, which enables white calibration in connection with the „CAL" button
CAL
Calibration button, which enables white calibration in connection with the „Function" button
REL
Button for simple comparison measurement (shows the difference between original and sample)
RGB/HSL Button for switching between RGB and HSL measuring mode
LIGHT
Button for turning the integrated sensor illumination on/off

Initial operation

Inserting the batteries
Before the initial operation of this meter, you must first install a new 9V block (alkaline) battery. A power pack
unit can be used optionally. Battery installation and power pack operation are described in the „Maintenance
and cleaning" section.

Connecting the measuring sensor

Connect the round plug of the sensor (17) with the socket „PROBE INPUT" (6) on the measuring device. The
plug is protected against wrong polarity and only fits into the socket in the right direction. Observe the arrow
marking on the plug. This marking points towards the back of the device. Make sure that the plug is firmly
inserted otherwise inaccurate measurements will be made.
Setting up the measuring device
For better reading, the measuring device can be set up using the bracket on the rear (13).
The device can be mounted on a tripod using the tripod socket (10)

Automatic cutoff function

To save on the unnecessary usage of battery power, an automatic switch-off function has been built-in. The
device is automatically switched off if no button has been pressed over a period of about 3 minutes. You can
switch the device back on with the „Power" button (3).
18

Werbung

Inhaltsverzeichnis
loading