DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM /
EN
APPLIANCE MODELS
Model
CN 03 050 EIS W - 500W
CN 03 100 EIS W - 1000W
CN 03 150 EIS W - 1500W
CN 03 200 EIS W - 2000W
CN 03 250 EIS W - 2500W
CN 03 300 EIS W - 3000W
* Minimum guaranteed heated volume (area) for heating at an average capacity of heat transmission
factor λ=0.5 W/(m
K) for a heated room. Higher values of heated volume (area) can be achieved at an
2
average value of λ=0.35 W/ (m
K). Standard height of heated rooms – 2.5 meters.
2
TABLE 2: INFORMATION REQUIREMENTS FOR ELECTRIC LOCAL SPACE HEATERS
Model identifier(s): 1.CN03 050 EIS W; 2.CN03 100 EIS W; 3.CN03 150 EIS W; 4.CN03 200 EIS W; 5.CN03 250 EIS W; 6.CN03 300 EIS W 230V~ 50Hz
Heat output
Nominal heat output
Minimum heat output (indicative)
Maximum continuous heat output
(indicative)
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
In standby mode
TESY Ltd
48 Madara Blvd,
Shumen, 9700,
Bulgaria
6
Operation and Storage Manual of Panel Heater
Heated volume
Heated area
10* - 15 m
3
4* - 6 m
2
20* - 30 m
3
8* - 12 m
2
30* - 45 m
3
12* - 18 m
2
40* - 60 m
3
16* - 24 m
2
50* - 70 m
3
20* - 28 m
2
60* - 80 m
3
24* - 32 m
2
P
0.50
1.00
1.50
2.00
nom
P
0.00
0.00
0.00
0.00
min
P
0.50
1.00
1.50
2.00
max,C
el
0.43
0.93
1.44
1.91
max
el
0.00
0.00
0.00
0.00
min
el SB
0.00033
Environment protection instructions
Obsolete electric appliances contain valuable materials and consequently they
should not be treated as domestic waste! We ask for your cooperation and your
active contribution to protect the resources and the environment. Please submit
your out-of-use appliances to the organized buy-back stations (if there are such).
Type of heat input for electric storage local space heaters only (select one)
2.50
3.00
kW
Manual heat charge control, with integrated thermostat
0.00
0.00
kW
Manual heat charge control, with room and/or outdoor temperature feedback
2.50
3.00
kW
Electric heat charge control, with room and/or outdoor temperature feedback
heat charge control, with integrated thermostat
Fan assisted heat output
2.45
2.91
kW
Type of heat output/room temperature control (select one)
0.00
0.00
kW
Single stage heat output and no room temperature control
kW
Two or more manual stages, no room temperature control
With mechanic thermostat room temperature control
With electronic room temperature control
With electronic room temperature control plus day timer
With electronic room temperature control plus week timer
Other control options (multiple selections possible)
Room temperature control, with presence detection
Room temperature control, with open window detection
With distance control option
With adaptive start control
With working time limitation
With black bulb sensor
[no]
[no]
[no]
[no]
-
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[no]
[no]
[yes]
[no]
[no]

Werbung