• With the foldable leg at the back of the outdoor transmitter the outdoor transmitter can be placed onto any flat
surface or wall mounted at the respective location by the hanging hole at the back of the unit. Placed outside,
choose a shady and dry position for the transmitter. (Direct sunshine falsifies the measurement and continuous
humidity strains the electronic components needlessly).
• Check the transmission of the signal from the outdoor transmitter to the base station (transmission range of
up to 30 m free field). Within ferro-concrete rooms (basements, superstructures), the received signal is nat-
urally weakened.
• If necessary choose another position for the outdoor transmitter and/or base station.
8. Care and maintenance
• Clean the devices with a soft damp cloth. Do not use solvents or scouring agents.
• Remove the batteries if you do not use the devices for a long period of time.
• Keep the devices in a dry place.

8.1 Battery replacement

• When the batteries of the outdoor transmitter are used up, the low battery symbol appears next to the out-
door temperature display.
• Change the batteries when the functions of the base station becomes weak.
• Please note: When the batteries are changed, the contact between outdoor transmitter and base station must
be restored – so always insert new batteries into both devices or start a manual outdoor transmitter search.
9. Troubleshooting
Problems
Solution
➜ Ensure that the batteries polarity are correct
No indication
➜ Change the batteries
at the base station
➜ No outdoor transmitter is installed
No transmitter reception
➜ Check batteries of external transmitter (do not use rechargeable batteries!)
Display "---"
➜ Restart the outdoor transmitter and the base station according to the
manual
➜ Manual search for the outdoor transmitter according to the manual
➜ Choose another place for the outdoor transmitter and/or the base station
➜ Reduce the distance between the outdoor transmitter and the base station
➜ Check if there is any source of interference
➜ Change the batteries
Incorrect indication
10. Waste disposal
This product and its packaging have been manufactured using high-grade materials and components which can
be recycled and reused. This reduces waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.
Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries from the device and dispose
of them separately.
This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive
(WEEE).
This product must not be disposed of in ordinary household waste. As a consumer, you are required
to take end-of-life devices to a designated collection point for the disposal of electrical and electronic
equipment, in order to ensure environmentally-compatible disposal. The return service is free of
charge. Observe the current regulations in place!
Disposal of the batteries
Never dispose of empty batteries and rechargeable batteries with ordinary household waste. They con-
tain pollutants which, if improperly disposed of, can harm the environment and human health. As a
consumer, you are required by law to take them to your retail store or to an appropriate collection site
depending on national or local regulations in order to protect the environment. The return service is
free of charge.
The symbols for the contained heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead.
11. Specifications
Measuring range
Indoor temperature
0 °C... +50 °C (+32 °F...+122 °F)
Outdoor temperature
-20 °C... +60 °C (-4 °F ...+140 °F)
15:11 Uhr
Seite 4
Instruction manual
Cat.-No. 30.3061
Indication: LL.L / HH.H
Temperature is outside measuring range
Range
max. 30 m (free field)
Transmission frequency
433 MHz
Maximum
radio-frequency power
< 10mW
Transmission time
60 seconds
Power consumption:
Base station: 2 x 1,5 V AAA (batteries not included)
Outdoor transmitter: 2 x 1,5 V AAA (batteries not included)
We recommend Alkaline batteries
Base station
Dimensions
77 x 26 (54) x 116 mm
Weight
77 g (instrument only)
Outdoor transmitter
Dimensions
56 x 21 (65) x 91 mm
Weight
46 g (instrument only)
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at
the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply entering the pro-
duct number in the search box.
EU Declaration of conformity
Hereby, TFA Dostmann declares that the radio equipment type 30.3061.02 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following Internet address:
www.tfa-dostmann.de/service/downloads/ce
www.tfa-dostmann.de
E-Mail: info@tfa-dostmann.de
Anleitung / Instruction / Instructions / Istruzioni / Instructies / Instrucciones
@ www.tfa-dostmann.de
TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, 97877 Wertheim, Germany
06/23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis