Switching Off - Falo 8 kW Gebrauchsanleitung

Keramikbrenner
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

mocouple to heat up and keep the valve open. At this point, simply regulate the burner power:
Ignition – REMOTE CONTROL mod.
WARNING! Some infrared remote controls, if pointed directly to the appliance may interfere
with its operation.
Regulation sequence, by pressing the button on the remote control or directly on the control
unit: ON, MAX, MEDIUM, MIN and OFF.
1 – Keep the ON/OFF button on the control unit (Fig. 6) pressed for about 4" until ignition
occurs. Once ignited, every time the ON/OFF button is pressed the appliance switches from
MAX to MEDIUM to MIN flame and finally OFF.
IMPORTANT! This ignition delay is not a "fault" in the electronic control unit but has been purpo-
sely designed by the Manufacturer to ensure appliance safety and prevent accidental ignition.
IMPORTANT! If the pilot flame goes out, accidentally or due to lack of gas, the gas supply will
be automatically interrupted by means of the installed safety device.
IMPORTANT! Avoid repeated ignition attempts: if the appliance does not operate imme-
diately, make sure ALL the installation operations have been performed correctly.
IMPORTANT! During operation and also after switch off, DO NOT TOUCH the protection gril-
les, the burner unit, the glass pipe and the cover dish. These are hot and could cause burns.
Power adjustment can also be made during appliance operation:
- MANUAL mod. (Fig. 5), by means of the ignition and adjustment knob.
- REMOTE CONTROL mod. (Fig. 6), by means of the remote control and with the button loca-
ted on the control unit.
IMPORTANT! If the appliance is fuelled by LPG in the open air and with temperatures below
2°C the use of Propane gas is recommended.

SWITCHING OFF

A - MANUAL mod.:
1 – Remove the side cover (Fig. 3: 15).
2 – Turn the control knob clockwise, returning this to position "0" (Fig. 5: 1).
3 – Correctly fit the side cover back on in reverse sequence.
B – REMOTE CONTROL Mod.:
1 – Press the ON/OFF button on the remote control (Fig. 6) or on the control unit on board the
appliance (Fig. 6).
2 – Remove the side cover (Fig. 3: 14 - 15) and close the gas supply tap.
IMPORTANT! IF THE APPLIANCE IS NOT USED FOR A LONG PERIOD, REMOVE THE
IGNITION BATTERIES (Fig. 4: 3), OF THE REMOTE CONTROL AND OF THE REMOTE
CONTROL UNIT (Fig. 4: 3) FROM THEIR HOUSING, TO PREVENT CORROSIVE LIQUID
LEAKING OUT AND CAUSING DAMAGE.