Herunterladen Inhalt Inhalt Diese Seite drucken

Belden 0980 XSL 3912-121-007D-01F Handbuch Seite 112

Vorschau ausblenden Andere Handbücher für 0980 XSL 3912-121-007D-01F:
Inhaltsverzeichnis

Werbung

12.3 REST API
Name
Datentyp
port_status
number
ds_fault
number
ds_fault_text
string
device
DEVICE Object
diag
array of DIAG (n)
DIAG Object
error
number
source
string
eventcode
number
eventqualifier
number
message
string
DEVICE Object
device_id
number
vendor_id
number
serial
string
baudrate
string
cycle_time
number
input_len
array of numbers (n) IOL input length in bytes
output_len
array of numbers (n) IOL output length in bytes
input_data
array of numbers (n) IOL input data
output_data
array of numbers (n) IOL output data
pd_valid
number
pdout_valid
number
FORCING Object
forcingActive
boolean
112
Beschreibung
Port status according to IOL
specification
Data storage error number
Textual data storage error.
IO-Link device parameters. → Null if
no IO-Link communication active
Array of port related events
Error code
Source of the current error.
Event code according to IO-Link
specification
Event qualifier according to IO-Link
specification
Error message
Standard parameters of the IOL-
Device
Baudrate (COM1,2,3)
Cycle time in microseconds
"1", if IOL input data is valid
"1", if IOL output data is valid
Forcing information of the device
Force mode is currently active
Handbuch CC-Link IE Field Basic
12 IIoT-Funktionalität
Beispiel
"device"
"master"
"Supply Voltage
fault"
Version 1.4 07/2023

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis