12 IIoT-Funktionalität
Name
Datentyp
forced
boolean
simulated
boolean
actuatorDiag
boolean
sensorDiag
boolean
maxOutputCurrent
number
_mA
current_mA
number
voltage_mV
number
PORT Object
port_type
string
iolink_mode
number
iolink_text
string
aux_mode
number
aux_text
string
cq_mode
number
iq_mode
number
Handbuch CC-Link IE Field Basic
Version 1.4 07/2023
Beschreibung
True, if the output pin of this channel is
forced
True, if the input value to the PLC of
this channel is simulated
True, if the output is in short circuit /
overload condition
True, if the sensor supply (Pin 1) is in
short circuit / overload condition
Maximum output current of the output
in mA
Measured current of the output in mA
(if current measurement is available)
Measured voltage of this output in mV
(if voltage measurement is available)
Textual representation of the IO-Link
port type
Current port mode:
0 = Inactive
1 = Digital output
2= Digital input
3 = SIO
4 = IO-Link
Textual representation of the current
port mode
Indicates the configured mode for the
Pin 2:
0 = No AUX
1 = AUX output (always on)
2 = Digital output (can be controlled by
cyclic data)
3 = Digital input
Textual representation of the current
aux mode
Port mode according to IOL
specification
Pin2 mode according to IOL
specification
12.3 REST API
Beispiel
"Digital Input"
"AUX Output"