Installing the filtered water tap
Note
The filtered water tap should be installed over a basin
connected to the sewage drain.
 Install filtered water tap as shown.
 Hole diameter: 12-15 mm
 Make sure the individual parts are arranged cor-
rectly during installation.
 Connect hose line to the filtered water outlet of the
unit.
 Connect hose line to the filtered water tap.
Alternatively, the filtered water tap can be mounted
directly to the wall using the included mounting
bracket.
Start up
Initial startup
The system should be filled and rinsed out before dis-
pensing water for drinking.
WARNING
Health risk due to the contamination with germs.
Pay attention to hygiene and cleanliness when inserting
and removing filter cartridges.
Do not touch the connections of the socket and filters.
Wear disposable gloves when inserting filters.
Do not damage the seals during installation and remov-
al.
The unit consists of three filter groups:
1
Upper activated carbon filter
2
Membrane filters (reverse osmosis)
3
Lower filter group (pre-filter)
Preparing filters for start-up
 Loosen the three filter chambers of the lower filter
group using the included spanner (black).
 Unscrew filter chambers.
 Remove filter inserts from the filter chambers and
remove the protective film.
 Screw on filter chamber with filter insert and hand-
tighten.
 Remove the supply hoses from the membrane fil-
ters and run them out of the sides of the unit into a
suitable container.
 Remove the upper activated carbon filter.
 Remove the membrane filter chambers from the
bracket one at a time.
 Unscrew and remove cap with included spanner
(black).
 Remove filter inserts (membrane filters) from the
packaging and remove the protective film.
 Insert filter inserts into the filter chambers as far as
they will go.
 Screw on the cap and hand-tighten.
 Place filter chambers in the brackets.
 Do not reconnect the supply hoses yet.
 Insert the upper activated carbon filter.
 Connect hoses (blue and red) for filtered water and
drain water concentrate to the outlets on the unit.
Rinsing out the three lower filters (pre-filters)
 Connect the unit to the water main.
 Make sure the two supply hoses for the membrane
filters are running to a suitable container (min. 10 li-
tres).
 Turn on filtered water tap.
The system begins filling with water.
 Plug in the mains plug.
 Rinse the system for at least five minutes to re-
move air and any production residue from the pre-
filters.
 Pull out the mains plug.
 Turn off filtered water tap.
 Dispose of the water in the container.
Rinsing the membrane filters (reverse osmosis)
 Take supply hoses out of the container and re-con-
nect them to the membrane filters.
 Open the bypass valve.
 Connect hoses (red and blue).
 Turn on filtered water tap.
 Plug in the mains plug.
The system begins filling with water.
The water will initially flow primarily out of the red
hose for drain water concentrate. This is normal.
 Rinse the system for at least five minutes to re-
move air and any production residue from the
membrane filters.
 Close the bypass valve.
Water will now flow out of both hoses (red and
blue).
 Rinse the system for another five minutes.
 Turn off filtered water tap.
 Pull out the mains plug.
The unit is now ready for use.
3
-
EN
Operation
 Turn on filtered water tap to dispense filtered water.
Shutdown
If the appliance will not be needed for more than 4 days:
 Shut off water supply.
 Pull out the mains plug.
Startup after shutdown
WARNING
Health risk due to increased micro-organism concentra-
tion in the water.
 Changing filter cartridges
 Rinse out the unit.
Using in a Kärcher WPD
Installing in a Kärcher WPD unit
Kärcher WPD units come with the WPC 100 RO in-
stalled.
The unit cannot be used in a WPD 100 with carbonating
function.
Kärcher Customer Service connects all hoses and per-
forms initial start-up.
Note
Should it be necessary to open the side parts for the in-
stallation and initial startup of the device, this may only
be done by a qualified electrician.
Initial start-up of Kärcher WPD unit
The WPD unit is required for initial start-up.
Before initial start-up in the WPD unit, the WPC 100
must be rinsed out and prepared as described in the
section "Initial start-up".
Initial start-up of the WPD drinking water dispenser is
described in the unit's operating manual.
Removing WPC 100 RO from a Kärcher WPD unit
Note
A factory-installed WPC 100 RO must be removed from
the WPD base before changing filters.
 Shut off water supply.
 Unpressurize the appliance: Press all buttons for
different types of beverages briefly until the system
is unpressurized. Avoid the appliance running dry.
 Switch off the appliance using the On/Off switch
 Disconnect the mains plugs (WPD and WPC).
 Open the Velcro strips.
 Remove the filter unit and set it in front of the unit.
 Filter change, see chapter "Care and maintenance
/ Replacing filter inserts"
 After the filter change, reassemble the unit in the
reverse order.
Dispensing water from a Kärcher WPD unit
Operation of the WPD drinking water dispenser is de-
scribed in the unit's operating manual.