Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Technical Data - BOMANN KB 7235 H Bedienungsanleitung, Garantie

Haushalts- kühlbox
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

where it will evaporate. Make sure the water dis-
charge opening does not get clogged. A light for-
mation of ice on the interior back during operation is
normal.
A permanently high power level can lead to in-
creased ice formation → set a lower power level and
wipe out the interior of the appliance.
Replacing the door hinge
If the appliance door starts to stutter, crack or jam
when you open it, it is probably due to a worn or
damaged hinge.
It is recommended to replace all door hinges at the
same time, otherwise the next repair will soon be
beckoning.
• Remove the contents of the appliance and the
movable interior parts.
• Tilt the appliance backwards and block it in this
position to prevent the door from sliding out.
• Loosen the hinge cover as described under
versing the door opening"
upper door hinge.
• Turn out the stand and disassemble the lower
door hinge.
• The respective hinge assembly is carried out in
reverse order.
• Open and close the appliance door for a test run,
readjust the hinges if necessary. In any case,
make sure that the door fits tightly and accurately.
"Re-
and disassemble the

Troubleshooting

Before you contact an authorized specialist
Problem / Cause / Action
Appliance is not working properly or at all
- Check the power supply / temperature setting /
ambient temperature.
- Unblock the ventilation openings, install the ap-
pliance freely.
Loading is too warm
- Check the temperature setting / ambient temper-
ature.
- A large quantity of warm food has been stored in
the unit in the last 24 hours.
- The appliance door is not closed properly, check
the door seal.
Loud noise during operation
- Check that the appliance is level.
"Operating noise"
- See
Water on the appliance bottom
- Check the temperature setting / water discharge
channel or opening.
Light does not work
- Check the power supply.
NOTE:
If a problem persists after following the steps above,
contact your trader or an authorized technician.

Technical Data

Climate class N/ST: this appliance is intended to be
used at ambient temperature ranging from 16°C to
38°C.
Electrical connection............................................
Power voltage: .........................220-240 V~ / 50 Hz
Rated power: ...............................................60 W
Rated current: ............................................0.3 A
23
.

Werbung

Inhaltsverzeichnis
loading