5. Timing Function Operation
The generator has timing function. The user can set the time
within 5 hours.
At the initial startup, the display screen displays "working time",
indicating that the timing shutdown function is not set and is in
continuous operation until the switch is pressed to shut down.
Press the "timing +"key to change the "working time"to "timing".
Press the "timing +"key once to increase the display number by 10
minutes. Press the "timing -"key to decrease the display number by
10 minutes. If the timinhg key is not pressed, the timing will be fixed
and decrease with the running time
After the set time, the oxygen generator will automatically shut down.
At this time, the display screen displays "timing --h --M", press the on
key to restart.
6. Voice operation
Press the "voice" button in the control button area to turn voice on
and off.
7. Shut down
If it is necessary to stop oxygen absorption temporarily during use,
press the "switch"key on the control panel to stop and start oxygen
supply.
After use, first press the "switch"key to stop oxygen production, then
urn off the power switch, then unplug the power plug and cut off the
power supply of the network.