COMPACT EXPERT SERIES
PAGE 6
It is used for saving the works performed.
a) PROGRAM
• Read / Write
Setting Range
In the "Read" status, parameters can be modified. When the "Write" status is reached, the program will be
ready to be saved.
The program number will be selected.
b) PROGRAM NO
• 0-99
Setting Range
After selecting the "Write" option in the program line, the program number you will save will be selected
from the "Program no" line. 100 programs are available between 0-99.
Program saving will be performed.
c) Save[Y(+)/N(-)]
• Yes (+) / No (-)
Setting Range
After selecting the program number, select "yes" on the last line "Save" button: Yes (Y) or No (N) Option H
will be selected. Press + to select yes. If you do not want to save, press "-" button to select no.
You can recall the programs stored in your machine's memory with the help of the torch trigger button
If you want to proceed with any of the previously saved programs, you can recall this previously saved
without having to go near the machine while working on the workpiece.
program by one of the following methods;
1) If you are at the point where you can reach the machine, the Program on the display will be as follows: You
can select "Read" and recall the program you want to use by reaching the "program no" page and perform
the operations on that program.
2) If you are not within the reach of the machine, you will need to rapidly press the torch trigger 2 times in
succession so that the program reading will be active. After pressing 2 times to switch to the desired
program number, press the trigger once to switch between the programs (this period will not exceed
5 seconds in the total of all these operations).
If you want to switch to program 1 and if the program was on "0" before: Quickly press the torch trigger twice
For Example;
and the program will be ready to be selected. After this operation, press the torch trigger one more time to
select program 1. If you wish to select program 2, you will need to press the torch trigger once again.
When the Double Pulse welding method is selected, double pulse frequency setting will be done.
D) D. PULSE FREQ (DOUBLE PULSE FREQUENCY)
• 0.5-5 Hz
Setting Range