Herunterladen Inhalt Inhalt Diese Seite drucken

Magmaweld COMPACT EXPERT-Serie Bedienungsanleitung Seite 22

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 91
22
Operation
PAGE 2
EN
Select the wire types
a) WIRE TYPE
The wire type to be used must be selected correctly.
• Fe
Setting Range
• CrNiER308
• AlMg 4.5Mn
Select the wire diameter.
b) WIRE DIA. (WIRE DIAMETER)
The wire diameter to be used must be selected correctly.
• 0.8-1.6 mm
Setting Range
Gas type will be selected.
c) GAS TYPE
The type of gas to be used must be selected correctly.
• 82/18
Setting Range
• %100 Ar
Material thickness is selected.
d) THICKNESS
The material thickness to be used must be selected correctly.
• 0.6-20 mm
Setting Range
While the smart mode is selected, if you select argon gas and wire as SG 0.8, the value 0 will be displayed on
Example;
the screen since this wire cannot be used with argon gas. If you see the value of 0 on the screen, in any case
something wrong has been selected in the menu such as method / wire type / gas mismatch.
USER MANUAL
• 307
• CuAl8
• CrNiER316
• Al 99.5
• FCW-B
• FCW-R
• 92/8
• 97,5/2,5
• %100 C02
COMPACT EXPERT SERIES
• CuSn
• 309L
• AlSi 5
• AlMg 5
www.magmaweld.com

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis