Operation
PAGE 4
EN
Trigger mode selection will be made.
a) TRIGGER
Setting Range
• 2 Trigger
• 4 Trigger
• 6 Trigger
• Method
Press the Trigger
2 TRIGGER MODE: When the torch trigger is pressed, welding starts and the trigger will be held pressed
until the welding ends. Releasing the trigger will end the welding.
• Press and hold the torch trigger.
Welding Start;
• Shielding gas flow starts as long as the pre-gas period.
• At the end of the pre-gas period, the wire feed motor
runs at a slow speed.
• Welding current increases when the workpiece is reached.
4 TRIGGER MODE: When the torch trigger is pressed and released once, welding starts and there is no
need to hold it pressed until the welding ends. Pressing and releasing the trigger again will end the welding
process.
• Press and hold the torch trigger.
Welding Start;
• Shielding gas flow starts as long as the pre-gas period.
• At the end of the pre-gas period, the wire feed motor
runs at a slow speed.
• Welding current increases when the workpiece is reached.
• Release the pressed torch trigger and the welding will continue.
USER MANUAL
Hold the Trigger Pressed
PrG : Initial Gas Time
PoG : Final Gas Time
I
PrG : Initial Gas Time
PoG : Final Gas Time
I
Release Trigger
• Release the pressed torch trigger.
Welding Termination;
• The wire feed motor will stop.
• The arc extinguishes after the set
burn-back time.
• The process ends after the final gas period.
: Welding Current
• Release the pressed torch trigger.
Welding Termination;
• The wire feed motor will stop.
• The arc extinguishes after the set
burn-back time.
• The process ends after the final gas period.
: Welding Current