8.
Unscrew the mounting ring (6) and remove
the nozzle.
9.
Clean the container, suction tube, air
cap and nozzle with a cleaning brush and
the appropriate cleaning solution.
1.
Attention: Never clean nozzle or air holes in
the spray gun with sharp metal objects. Do
not use solvents or lubricants containing
silicone.
9.
Turn both knobs (11) on both sides of the
Air Compressor Assembly to the "Unlock"
position, pull and separate the spray gun
from the air compressor assembly.
10. (a) Clean the rear of the spray gun with
the appropriate cleaning solution.
(b) Turn the suction tube clockwise and
pull the suction tube out of the gun.
Open the bayonet lock and separate
the two parts of the suction tube. Clean
the suction tube with a suitable clean-
ing solution.
Attention: The seal ring between both
parts of the suction tube must be put
back into place after cleaning. Other-
wise, some paint in the container will be
sucked into the air duct and interfere