4. Maintenance

4.1. Stuffing box
Generally a damaged or leaking spindle packing has to be changed or tightened immediately, otherwise a new packing can leak
again after a short period.
Spindle packing design is shown in the relevant technical data sheets. Spindle packings are available as a spare parts set from
the manufacturer. For ordering a replacement spindle packing always give the serial number of the valve (found on the name
plate "W. Nr.").
4.2. Changing a spindle packing
ensure valve and piping are pressure less and empty
in order to replace the spindle packing the actuator must be removed (for this procedure, see the operating instructions for the actuator
in question).
loosen and remove cap nut (411)
remove the old packing set and clean packing compartment
clean valve spindle
insert new packing set according to sectional drawing
tighten cap nut (411) and fit actuator onto valve and check limit switches
Caution!
For pure graphite packing, too strenuous tightening will cause high friction, which detracts from the valve
operation.
4.3. Changing a bellows seal
The bellows seal and plug assembly is one unit and must always be changed together. Therefore new bonnet gaskets (503) are
also necessary.
ensure valve and piping are pressure less and empty .
In order to replace the bellows seal the actuator must be removed (for this procedure, see the operating instructions for the actuator in
question).
two-way and diverting valves:
mixing valves:
remove safety stuffing box (441)
open screw (451) and grub screw (449)
remove plug assembly (300)
remove gasket (444) and clean gasket area
assemble new plug (300) and new gasket (444). Put in grub screw (449) to prevent twisting
assemble new safety stuffing box (441)
two-way and diverting valves:
mixing valves:
(for tightening torques, please see table in appendix)
fit actuator onto valve and check limit switches for applicable torque, (for this procedure, see the operating instructions for the actuator
in question).
12/2017
remove bonnet (201) from body (101)
remove B-flange (601) from body (101)
assemble bonnet (201) with plug assembly (300) and valve body (101)
assemble B-flange (601) with body (101) and tighten bolts gradually, diametrically