Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Troubleshooting - Senco XtremePro Serie Betriebsanleitung

Vorschau ausblenden Andere Handbücher für XtremePro Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 13
EN
TOOL ELEMENTS
Finish Nailer
FN2
FN1
FN1
Workpiece Contact
FN2
Exhaust
FN3
Trigger
FN4
Magazine
FN5
Inlet
FN6
Exhausr Rear

MAINTENANCE

Warning
y
Repairs other than those described here should be
performed only by trained, qualified personnel. Contact
SENCO for information at:
+31 320 295 575.
y
Read section titled "Safety Warnings" before maintaining
tool.
y
Only use spare parts specified by manufacturer or autho-
rized representative.
_______________________________________________
y
All screws should be kept tight. Loose screws result in
unsafe operation and parts breakage.
y
Check monthly
_______________________________________________
y
With tool disconnected, make daily inspection to assure
free movement of workpiece contact and trigger. Do not
use tool if workpiece contact or trigger sticks or binds.
_______________________________________________
y
Squirt Senco pneumatic oil (5 to 10 drops) into the air
inlet twice daily (depending on frequency of tool use).
Other oils may damage O-rings and other tool parts.
y
Some Senco tools are Oil Free and DO NOT require oil,
Check label.
_______________________________________________
y
Wipe tool clean daily and inspect for wear. Use non-
flammable cleaning solutions only if necessary.
y
Do Not Soak.
y
Caution: Such solutions may damage O–rings and other
tool parts.
y
Dispose of cleaning materials properly.
FN5
FN6
FN4
FN3
Framing Nailer
FN8
FN7
FN7
Workpiece Contact
FN8
Exhaust
FN9
Trigger
FN10
Magazine
FN11
Inlet
FN12
Exhausr Rear
FN13
Feeder Shoe
TROUBLE SHOOTING
SYMPTOM
Air leak near top of tool. / Sluggish operation
1
SOLUTION
Verify air supply / tighten screws or install Repair
Kit – See Parts Manual
SYMPTOM
Air leak near bottom of tool / Poor return.
2
SOLUTION
Clean tool / tighten screws or install Repair Kit
See Parts Manual
SYMPTOM
Other problems.
3
SOLUTION
Contact SENCO.
8
FN11
FN12
FN10
FN9
FN13
Should Staple Jam Occur:
Disconnect Air Supply
Remove Fasteners
Clear the Jam
Follow loading Procedure

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis