  • DEUTSCH, seite 30
10. Configuration button (PROGRAM);
11. Connector for hearing aid coil (ILA) Ref. 1168/48
12. Trimmer for adjusting speaker volume (RV1)
13. Module connection wire connector (OUT)
14. Label with MAC ADDRESS of the device
15. Jumper provided to connect the door state sensor
16. Terminal board

4. DESCRIPTION OF TERMINALS

]
PA
Hall button
]
LINE
Bus line in
]
SE2
Garage relay contacts
SE -
Pedestrian electrical lock with capacitance discharge actuation negative
SE +
Pedestrian electrical lock with capacitance discharge actuation positive
5. ESSENTIAL PARAMETER CONFIGURATION (WITHOUT WiFi
CONNECTION)

5.1. CONFIGURABLE PARAMETERS

The essential parameters can be configured directly on the door unit without needing a WiFi connection.
The configuration is performed directly on the device. The parameters listed below can be configured and
the value can be set by means of LEDs (1) and (4).

5.1.1. PARAMETER 1: door unit type

This parameter is used to set the door audio and audio-video door unit as primary or secondary. All the
users in the system may be called from the main door unit. A secondary door unit may only call the users of
the riser to which it belongs. Users who receive the call can identify the source of the call by the tone.

5.1.2. PARAMETER 2: door unit ID

If main door unit type is set under previous parameter, this parameter can be used to change the ID from 0
to 1 because various main calling stations with different ID can be present in the system.
If, on the other hand, a "secondary" door unit type is set under previous parameter (which by default is
named riser 0), this parameter can be used to change the ID from 0 to 1 because two secondary calling
stations with different ID can be present in the same riser.

5.1.3. PARAMETER 3: door opener

This is used to manage lock door opener mode; possible options are "Free" or "Privacy". In "Privacy" mode,
DS1083-117B