en Troubleshooting
Fault
The temperature dif-
fers greatly from the
setting.
The appliance hums,
bubbles, buzzes,
gargles, clicks or
crackles.
The appliance makes
noises.
56
Cause and troubleshooting
Different causes are possible.
Switch off the appliance. → Page 46
1.
Switch the appliance back on after five minutes.
2.
→ Page 46
If the temperature is too warm, check the temper-
ature again after a couple of hours.
If the temperature is too cold, check the temper-
ature again on the following day.
Not a fault. A motor is running, e.g. refrigerating unit,
fan. Refrigerant flows through the pipes. The motor,
switches or solenoid valves are switching on or off.
Automatic defrosting is running.
No action required.
The appliance is not level.
Align the appliance using a spirit level and the
screw feet.
The appliance is not free-standing.
Observe the minimum clearances for the appliance.
Fittings wobble or stick.
Check the removable fittings and, if required, re-
place these.
Bottles or containers are touching.
Move the bottles or containers away from each
other.
Super freezing is switched on.
No action required.