Display unit
The measured value and the values for SPx, rPx can be
displayed in the following units:
bar, PSI, MPa .
Select the display unit before setting the values for the
parameters SPx, rPx. This avoids rounding errors generated
internally during the conversion of the units and enables exact
setting of the values.
Setting at the factory: Uni = bAr.
Min-Max memory for system pressure
• HI: displays the highest measured pressure
• LO: displays the lowest measured pressure (only PY9294)
Erase the memory:
- Press the "Mode/Enter" button until HI or LO is displayed.
- Press the "Set" button and keep it pressed until "- - - -" is
displayed.
- Then press the "Mode/Enter" button briefly.
Delay time for the switching outputs
dSx = switch-on delay; drx = switch-off delay.
The output does not immediately change its switching status
when the switching condition is met but when the delay time
has elapsed. If the switching condition is no longer met when
the delay time has elapsed, the switching state of the output
does not change.
• Setting range: 0 (= delay time not active) - 0.2 ... 50 s,
• in steps of 0.2 s.
dS2 / dr2 are not active if OU2 = dESI.
Output polarity
2 options can be selected:
- PnP = positive switching / - nPn = negative switching
This setting applies to both switching outputs.
Damping for the switching outputs
Pressure peaks of short duration or high frequency can be
filtered out.
dAP-value = response time between pressure change and
change of the switching status in ms.
• The value for dAP defines the switching frequency (f) of the
output:
dAP
3
6
f [Hz]
170
80
10
17
30
50
30
16
60
125
250
8
4
2
500
1
23