Operation
7.3

Menu Functions

88
Siemens Building Technologies
Fire Safety & Security Products
The menu selection can be called and exited using the following keys:
Keys
Keep
pressed
Basic parameter
Device address
Baud rate S1
Parity S1
Baud rate S2
Parity S2
Signal transmitter
Language
Auto logout
Interface settings
Mode COM1
Protocol COM2
Joystick mode
Change PIN codes
Administrator
User1
Key disabling
"Mem" key
Maintenance support
Joystick calibration
Joystick test
LCD test
Key test
Firmware version
Description
Call menu selection. The LCD displays the following:
"Parameterization menu
Basic parameters"
Exit menu selection. The LCD displays the following:
"Parameters modified
Cancel
Save"
Select desired menu item using the joystick, and press "F10" again.
Description
Device address between 0 and 99.
Baud rate for serial port COM /COM1A:
1,200, 2,400, 4,800, 9,600 or 19,200 baud
Parity for serial port COM /COM1A:
none or even (odd parity cannot be set!)
Baud rate for serial port COM2:
2,400, 4,800, 9,600 or 19,200 baud
Parity for serial port COM2:
none or even (odd parity cannot be set!)
Switch signal transmitter on/off.
Prerequisite: the signal transmitter must be switched on using DIP
switch SW301-8 (see Section 4.3).
German or English. The language setting is effective immediately.
Time after which the CKA4820 automatically switches to the LOGOFF
status; adjustable between 000 and 200 min (000 = no Auto logout
time).
Description
Setting of operating mode, see Sections 7.6 to 7.10.
Setting of used protocol, see Sections 7.6 to 7.10.
Switching between analog control (telemetry devices are controlled
with variable speed) and digital control (fixed motion speed of
telemetry devices).
Description
Change PIN code for administrator, see Section 6.3.
Administrator login required.
Change PIN code for user, see Section 6.3.
Administrator login required.
Description
If key disabling is set to "Disable", pressing the "Mem" key does not
trigger a function.
Administrator login required.
Description
Calibration of joystick, see Section 11.2.
Function test of joystick. When moving in one direction, the LCD
displays the corresponding X, Y or Z coordinate until the function is
exited using F10.
Function test of LCD. The available characters are displayed in
sequence until the function is exited using F10.
Function test of keys. The LCD displays the designation of each key
until the function is exited using F10.
Output of firmware release.