5
Leave the scale in the condition of Fig. 3-7 for one hour or more until the scale temperature stabilizes.
6
Secure the remaining scale clamps by gradually and alternately tightening screws A and B. (Use only
the right-side scale clamp for clamps with two screws, and use the right-side and the left-side scale
clamps for clamps with three screws.) (Final fastening torque: 1.4 N . m)
BL55-006RE, 026RE, 046RE, 066RE, 086RE, 106RE
B
A
7
Tighten the remaining scale clamps in the same way starting from the inner side and moving towards the
outside. (Final fastening torque: 1.4 N . m)
Spacer
Spacer
8
Check the surface of the scale for oil and dust. If the surface is dirty, wipe it clean with gauze moistened
with alcohol. Be sure to wipe off oil and dust on the surface thoroughly.
BL55-RE
A
Fig. 3-9
BL55-026RE, 046RE, 066RE, 086RE, 106RE
B
A
BL55-036RE, 056RE, 076RE, 096RE
B
A
Fig. 3-10
BL55-016RE, 036RE, 056RE, 076RE, 096RE
A
B
B
A
B
A
B
3-7