Note:
If the test leads are open or if the resistance of the circuit to
be tested exceeds 660 Ω, the overload indicator "OL" is
displayed.
Continuity Test Function
Range
Open circuit voltage:
Overload protection:

Measuring Capacitance

Warning! To avoid electric shock and damage to the meter,
discharge any capacitor before measurement! Do not discharge
the capacitor by a short circuit, but by bridging the connections
using a 100 kΩ resistor (depending on the size of the capacitor).
Never connect the measuring probes of the meter to a power
source if you have selected the capacitance measuring range as
this will damage the meter. Before a capacity measurement,
measure to safety whether a capacitor still is charged (use the
DC V area).
1. Connect the black measuring cable to the COM jack (9) and
the red measuring cable to the input jack (10).
2. Set the rotary function switch (13) to the
3. Connect the measuring cables to both ends of the capacitor to
be tested.
4. Read the measuring value from the display.
Operation
Resolution
0.1 Ω
Approx. 1.2 V
250 V DC or 250 V rms AC
Function
The built-in buzzer sounds if the
resistance is lower than 30 Ω.
61
position.