Herunterladen Inhalt Inhalt Diese Seite drucken

Siemens SIMATIC FS400 Anleitung Seite 160

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The machine interface is available in the following design types:
Transmitter interface
Connection system
Cable gland, PG13.5
(standard)
Hirschmann plug
(6-pin+FE)
MIN-style plug (5-pin)
M12 plug (3-pin)
M12 plug (5-pin)
Table 7.0-1:
By changing the polarity on the voltage supply, extended functions can be selected on
the SIMATIC FS400 3RG7845 receivers with PG 13.5 cable gland, MIN-stype plug,
Hirschman plug and M12 plug. These functions are dynamic contactor monitoring,
start/restart interlock and minimum restart delay time.
160
Machine interface
Receiver/transceiver
Safety-related switching
outputs (OSSDs - output
signal switching devices)
Transistor outputs
Transistor outputs
Transistor outputs
AS-Interface Safety at
Work
Transistor outputs
Machine interface selection table
Connection system
Cable gland, PG13.5
Hirschmann plug
(6-pin+FE)
MIN-style plug (7-pin)
M12 plug (3-pin)
M12 plug (8-pin)

Quicklinks ausblenden: