GB
MT
2. Insert around 5 g of commercially-avail-
able lubricating grease into the lubrica-
tion opening on the gearbox housing.
3. Close the gears again using the screw
(57).
Adjusting the Carburettor
The carburettor is preset in the factory for
optimal performance. If subsequent adjust-
ments are required, have them carried out
by a specialist workshop.
Removing blockages
Switch the device off and re-
move the spark plug connec-
tor (
2) before you work on
A
the cutting unit.
Wear protective gloves in order to
avoid cutting yourself.
Table "Maintenance Intervals"
Machine Part
Screws, nuts, bolts
Air filter
Fuel filter
Spark plug
Fuel hoses
Complete machine
Operating handle
Cutting head
Coupling
Lubricating the
50
Action
Check, tighten
Clean or replace
Replace
Clean/adjust/replace
Check, replace if necessary
Check, clean if necessary
Check for function
Check correct installation
Check that the device is sta-
tionary when idling
gears
Checking the coupling
Place the device on a firm level sur-
face. Make sure that the cutting tool
does not touch either other objects
or the ground.
Before each use, check that the coupling is
working correctly when idling.
Start the device (see "Starting the engine")
and carry out a visual check at a sufficiently
safe distance to verify that the thread spool is
not turning when the device is idling.
Maintenance Intervals
Regularly carry out the maintenance work
listed in the "maintenance intervals" table.
Regular maintenance prolongs the life
of the equipment. It also gives optimum
cutting performance and avoids accidents.
Before
Each Use
Operating Hours
10
20

Werbung