Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BES 516-300-S345-S4-N Betriebsanleitung Seite 6

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BES 516-300-S34 _ -S4-N
Induktive Sensoren
FM Control Drawing CD 1
HAZARDOUS (CLASSIFIED) LOCATION
FM-US:
Class I, Division 1,
Groups A, B, C, D, T4
Class I, Zone 0, AEx ia IIC
FM-CA:
Classe I, Division 1,
Groupes A, B, C, D, T4
Classe I, Zone 0, Ex ia IIC
Note:
T4 temperature code based on 70 °C ambient
temperature range -25°C to +70°C
NAMUR
I
BES 516-300-S...-S4-N SERIES
INDUCTIVE PROXIMITY SWITCHES
Vmax
=
12 V
Imax
=
50 mA
Pi
=
120 mW
Ci
=
30 nF
Li
=
0.5 mH
1.
The con guration of associated Apparatus must be FM Approved
(CSA Certi ed or FM-Canada Approved when installed in Canada)
under Entity Concept.
2.
BES 516-300-S...-S4-N Series may be installed within the Hazardous (Classi ed)
location for which it is approved.
3.
Installation in the United States should be in accordance with the
National Electric Code, NFPA 70, Article 504.
4.
Installation in Canada should be in accordance with the Canadian Electrical Code,
CSA C22.1, Part 1, Appendix F.
5.
No revision to this drawing is permitted without FM or CSA approval.
3
deutsch
All manuals and user guides at all-guides.com
NONHAZARDOUS (UNCLASSIFIED)
LOCATION
FM-US:
FM-CA:
R
v
1
2
APPROVED BARRIER/
ASSOCIATED EQUIPMENT FOR
FM APPROVED SENSORS
APPROVED BARRIER/
ASSOCIATED EQUIPMENT FOR
CFM APPROVED SENSORS
ASSOCIATED APPARATUS
WITH ENTITY PARAMETERS
Voc (or U0)
Vmax (or Ui)
Isc (or Io)
Imax (or Ii)
Po
Pi
Ca (or Co)
Ci + Ccable
La (or Lo)
Ci + Ccable
Zündschutzart „ia"
eigensicher

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bes 516-300-s346-s4-nBes 516-300-s347-s4-n

Inhaltsverzeichnis