Herunterladen Inhalt Inhalt Diese Seite drucken

Wood's AC Venezia Silver 18K Duo Bedienungsanleitung Seite 18

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43
Operating Instructions
GB
PROBLEM
CAUSE
Unit does not start
Water full indicator lamp blinks and water tank is full.
when pressing on/off
button
Room temperature is higher than the setting temperature
(Electric heating mode)
Room temperature is lower than the setting temperature.
(Cooling mode)
Not cool enough
The doors or windows are not closed.
There are heat sources inside the room.
Exhaust air hose is not connected or blocked.
Temperature setting is too high.
Air inlet is blocked.
High noise level
The ground is not level or not flat enough
The sound comes from the flowing of the refrigerant inside the
air conditioner
If you are having trouble with your dehumidifier, please refer to below trouble shooting. If nothing of the below
works, please contact your retailer for servicing of your Air Conditioner.
ERROR CODES
CAUSE
E0 Code
Room temperature sensor failed
E2 Code
Water tank full when cooling
E3 Code
Evaporator temperature sensor failed
18
1
REMEDY
Dump the water out of the water tank.
Reset the temperature
Reset the temperature
Make sure all the windows and doors are closed.
Remove the heat sources if possible
Connect or clean the exhaust air hose.
Reset the temperature
Clean the air inlet.
Place the unit on a flat, level ground if
It is normal.
REMEDY
Replace room temperature sensor (the unit can also work
without replacement.)
Take off rubber stopper and empty the water.
Replace evaporator temperature sensor
possible