Features
Image acquisition
Once the alarm system is activated, three 640x480 pixel images or six 320x240 pixel images are acquired when motion is detected.
The detector can also be used to acquire images manually using a remote control (app, portal or local control panel).
Initialisation period
The detector is initialised for 40 seconds when the control unit enters activation mode or when the detector is set to Test. The
detector does not manage intrusions or movements. If the battery of the detector is flat or if the tamper switch is open, the blue LED
lights up during the initialisation period.
Sleep Time
When the JP2 is set to Off, the detector will respect a "sleep time" of approximately 1 minute to save energy. If the system is active,
the detector will not repeat the transmission for 1 minute if motion is detected after the transmission. Any motion detected during
this time will reset the sleep time (taking back to 1 minute). Consequently, continuous motion in front of the detector will not
discharge the battery.
Battery and flat battery detection
The detector is powered by two AA 1.5 V alkaline batteries.
The detector is provided with the flat battery detection function. When the battery voltage is flat, the detector transmits the flat
battery signal to the control unit. If a flat battery condition is detected, the blue LED lights up for two seconds.
While replacing the batteries, after having removed the flat batteries, press the tamper switch or the function button twice to
discharge the device completely before inserting the new batteries.
<NOTE>
During replacement, pay particular attention not to damage the contacts in the battery holder compartment.
Tamper protection
The detector is protected by a tamper switch which is compressed (closed) when the detector is fixed to the wall or the corner
bracket is applied. When the tamper switch is opened the detector sends a tamper open signal to the control unit to inform the
user. If a motion is detected while the tamper switch is open, the blue LED lights up for two seconds.
Supervision
The detector regularly transmits a supervision signal to indicate the condition according to the user's setting. The user may also
press the function button once to manually transmit the supervision signal.
Test mode
The Test mode is used to control the detection coverage of the device not the communication range with the control unit.
To access Test mode: hold the function button pressed for five seconds. The blue LED will light up and stay on for
approximately 30 seconds after having released the button. Test mode, which lasts for 3 minutes, will start after this time.
The detector will start initialisation during the first 30 seconds. The detector does not manage intrusions or movements
during this time.
Motion detection in front of the detector can be checked at the end of the initialisation period. The blue LED lights up for
two seconds after detection.
<NOTE>
Check that the "Rest Time" function is not enabled before entering Test mode.
Setup
Guidelines
- Check that the control unit is working before inserting the batteries in the device.
- Check that the control unit is within the working range while the device is in use.
- A device may be removed from the system only after having removed the battery. This prevents unnecessary battery
consumption.
Connecting to the system
The detector must be learnt by the control unit to transmit the signal if motion is detected. Proceed as follows to perform the device
learning procedure.
The detector may be learnt by the control unit only within three minutes from switch-on.
1.
Remove the battery compartment lid and insert the two AA batteries (included).
2.
Make sure that the tamper switch is open (released).
3.
Make sure that the learn function has been activated on the control unit. Within three minutes from switch-on, hold
the function button pressed for 3 seconds and then release it when the blue LED and the illuminator blink once. The
Blue LED will light on for 25 seconds in learning mode, add PIR Camera into the Control Panel during this period (refer
to your Control Panel to finish learn in process). If the PIR is successfully added into the Control Panel, the Blue LED
will flash 6 times to indicate. If PIR is not added within 25 seconds, please repeat learning process.
4.
After having been leant by the control unit, the detector is automatically recorded in the system. Check the control unit
to check that the learning and registration procedure were performed correctly.
Walk Test
Run a Walk test before installing the detector at the chosen point:
1.
Make sure that the Walk Test function has been activated on the control unit.
2.
Press the function button once.
6