Description
2
Description
2.1
Product overview
6
5
4
3
2
1
12
1
Connector
2
Control valve
3
Inner mask
4
Visor
5
Visor frame
6
Upper head-harness connector
7
Harness
8
Face seals
9
Carrying strap
10 Mask body
11 Clamping ring
12 Exhalation valve cover
12
7
8
10 9
11
(approved by Dekra Exam)
2.2
Feature description
The full face masks have a round-thread connector for the respiratory
filter with an Rd40 x1/7 thread. The full face masks can be used at
temperatures from -30 °C to +60 °C.
Mask spectacles can be inserted for users who wear spectacles.
2.3
Intended use
The full face masks protect the face and eyes against aggressive
media.
2.4
Limitations on use
WARNING
!
Beards and sideburns in the sealing area of the full face mask
will cause leakages! Therefore the full face mask should not
be used by anyone with facial hair of this sort. Earpieces in
the sealing area also cause leakages. Use special mask
spectacles.
2.5
Approvals
The full face masks are approved according to:
EN 136:1998 CL. 3
NIOSH regulations
AS/NZS 1716:2012.
(EU) 2016/425
Declaration of conformity: see www.draeger.com/product-certificates
The full face masks may only be used with approved respiratory filters.