Herunterladen Diese Seite drucken

Axis Communications A1610-B Installationsanleitung Seite 6

Vorschau ausblenden Andere Handbücher für A1610-B:

Werbung

AXIS A1610-B Network Door Controller
Do not connect the Axis product to a receptacle controlled by a switch.
Battery
-
The 3.0 V lithium battery used by the Axis product is a UL recognized
component. (Type: BR2032, diameter: 20 mm (0.78 in), manufacturers:
Power Glory (Omnergy)). The following battery type is also a UL recognized
component: Type CR2032.
-
Users shall not replace the battery. If the battery needs replacing, it must
be done by a trained technician only.
-
Used batteries shall be disposed of according to local laws and regulations,
which may vary from state to state. Waste BR/CR lithium cells are neither
listed nor exempted from the USEPA hazardous waste regulations. Waste
lithium batteries can be considered reactive hazardous waste if there is a
significant amount of unreacted, or unconsumed lithium remaining. For
information about how to dispose of used lithium batteries, contact your local
authority for waste disposal.
Specifications
Operating conditions
Normal use (not evaluated by UL)
UL 294
Wiring requirements
-
UL listed or R/C AWM wires that have a conductor gauge range of
AWG 22–14 shall be used.
-
The minimum conductor gauge for connection between the power sourcing
equipment (PSE) or power injector and the powered device (PD) is 26 AWG.
-
Minimum PoE category 5e, shielded cable, required for PoE.
-
This product is not intended for outside wiring as covered by Article 800 in the
National Electrical Code, NFPA 70.
Connectors
-
Power Connector – For UL security applications, the product shall be powered
by a UL 294 or UL 603 listed Class 2 low-voltage power SELV and limited
power supply with appropriate ratings.
-
External power to relays - If the relays are connected to an external power
source this must be UL 294 listed Class 2 low-voltage power SELV and limited
power supply.
-40 °C to 55 °C (-40 °F to 131 °F)
Humidity 20–85% RH (non-condensing)
0 °C to 55 °C (32 °F to 131 °F), maximum
humidity 85%.
Intended for use in UL listed enclosure with
tamper switch.
6