BOS 50K-PA-PR10-S4
Photoelectric Sensors – Retro-reflective sensor
User's Guide
Product information
These photoelectric sensor have the following features:
High quality polarizing filter for enhanced, reliable
reflection rejection with shiny objects
Optical bandpass filter for greatest possible ambient
light rejection
Excess gain indicator for high operating reliability
Highly visible light spot for ease of alignment
Rugged housing
BOS 50K-PA-PR10-S4
Red light retro-reflective sensor with polarizing filter
Order code: BOS01CR
Switching output PNP
normally open – normally closed, Pin 4 – 2
Range s
0...18 m
r
Safety notes
These photoelectric sensors may not be used in applica-
tions where personal safety depends on proper function of
the devices (not designed in accordance with EU Machi-
nery Directive). Read these operating instructions carefully
before putting the device into service.
Do not look directly into the light beam to avoid temporary
irritation to the eyes.
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
For use in the secondary of a class 2
source of supply.
Pour une utilisation dans le secondaire
d'une source d'alimentation de classe 2.
Connection
For UL: Connect proximity switches only by using any R/C
(CYJV2) cord, having suitable ratings.
Connectez les détecteurs de proximité uniquement à l'aide
d'un cordon R/C (CYJV2) de valeur nominale appropriée.
PNP
M12
1
english
1
+
2
4
-
3
Installation
CAUTION
Red light
If you look into the light beam, temporary blinding and
irritation of the eyes is possible.
► Locate the sensor so that it is not possible to look
into the light beam even during operation.
For operation no further precautions are required (Exempt
group acc. IEC 62471).
28.5
a
b
a = Optical axis receiver
b = Optical axis emitter
Display- and operating elements
green LED:
Operating voltage / error indicator
green LED:
Light reception idicator / stability indicator
270°-potentiometer
for precise setting of the switching distance
The green LED Power on indicator / error indicator
LED on: The sensor is operating.
LED flashes: Short circuit or output overload (Pin 4)
The yellow LED Light reception indicator / stability
indicator
LED on: Light at the receiver, Excess gain > 1.5.
LED flashes: Light at the receiver, Excess gain ≤ 1.5.
Potentiometer
Used for setting the switching distance.
5.5
a
62
3
b
18.5
7.5

Werbung