NORSUP CARTRIDGEFILTER
IMPORTANT SAFETY INSTRUCTIONS
These operating instructions contain important
information on the safe, proper and economical
operation of this swimming pool appliance. Strict
observation of the operating instructions will help
to avoid dangers, reduce repair costs, shutdown
times and increase the reliability and working life
of the product.
Failure to follow the instructions in this manual may
result in serious adverse health effects, or even serious
or fatal injur y. Failure to follow the instructions in this
manual will in all cases invalidate all guarantees and
liability on the part of the manufacturer.
Consumer Information and Safety
This Cartridge Filters are designed and manufactured
to provide years of safe and reliable operation. Operated
and maintained according to the information in this
manual and the installation codes referred to in later
sections.
THIS FILTER OPERATES UNDER HIGH PRESSUR
When any part of the circulating system, (e.g., closure,
pump, filter, valve(s), etc.), is ser viced, air can enter the
system and become pressurized. Pressurized air can
cause the top closure to separate which can result in
severe injury, death, or property damage. To avoid this
potential hazard, follow these instructions: •
1. If you are not familiar with your pool filtering system:
(1) Do NOT attempt to adjust or ser vice without
consulting your dealer, or a qualified pool
technician.
(2) Read the entire Installation & Operation
Manual before attempting to use, ser vice or
adjust the pool filtering system.
2. Before repositioning valve(s) and before beginning
the assembly, disassembly, or any other ser vice of
the circulating system:
(1) Turn the pump OFF and shut OFF any
automatic controls to ensure the system
is NOT inadvertently started during the
ser vicing.
(2) open the manual air release valve.
(3) Wait until all pressure is relieved.
3. Whenever installing the filter closure follow
the filter closure warnings exactly.
4. Once ser vice on the circulating system is complete
follow initial start-up instructions exactly.
6
WWW.NORSUP.EU
5. Maintain circulation system properly. Replace
worn or damaged parts immediately, (e.g.,
closure, pressure gauge, valve(s), O-rings, etc.).
6. Be sure that the filter is properly mounted and
positioned according to instructions provided.
WARNING
This filter must be installed by a licensed or
certified electrician or a qualified pool service
man in accordance with the Local Code and all
applicable local codes and ordinances.
Improper installation could result in death or
serious injury to pool users, installers, or others
and may also cause damage to property.
Always disconnect power to the pool circulating
system at the circuit breaker before ser vicing
the filter. Ensure that the disconnected circuit
is locked out or properly tagged so that it cannot
be switched on while you are working on the
filter. Failure to do so could result in serious
injury or death to service man, pool users or
others due to electric shock.
WARNING
Do not operate the filter until you have read and
understand clearly all the operating instructions
and warning messages for all equipment that is a
part of the pool circulating system. The following
instructions are intended as a guide for initially
operating the filter in a general pool installation.
Failure to follow all operating instructions and
warning messages can result in property damage
or severe personal injury or death.
WARNING
To reduce the risk of injury, do not permit children
to use this product unless they are always closely
super vised.
Alterations which serve the technological progress as well as errors excepted!
NORSUP CARTRIDGEFILTER
Due to the potential risk that can be involved it is
recommended that the pressure test be kept to
the minimum time required by the local code. Do
not allow people to work around the system when
the circulation system is under pressure test. Post
appropriate warning signs and establish a barrier
around the pressurized equipment. If the equipment
is in an equipment room, lock the door and post a
warning sign.
Never attempt to adjust any closures or lids or attempt
to remove or tighten bolts when the system is pres-
surized. These actions can cause the closure to separate
and could cause severe personal injury or death if
they were to strike a person.
Never exceed the maximum operatingpressure of
the system components. Exceeding these limits
could result in a component failing under pressure.
This instantaneous release of energy can cause the
closure to separate and could cause severe personal
injury or death if they were to strike a person.
HYPERTHERMIA
SPA water temperature excess 38°C (104°F) may
be injurious to health. Measure water temperature
before entering SPA.
Hyperthermia occurs when the internal temperature
of the body reaches a level several degrees above the
normal body temperature of 98.6 °F (37 °C). The symp-
toms of hyperthermia include drowsiness, lethargy,
and an increase in the internal temperature of the body.
Alterations which serve the technological progress as well as errors excepted!

1. OVERVIEW

CF series cartridge filter combines superior water
filtration with ease of operation and corrosion-free
construction. With filtration ratings of 5,100~ 8,910
gallons (19,305 ~ 33,700 liters) per hour, they are
designed for continuous or intermittent operation, for
installation above or below the pool waterline, for fresh
or saltwater swimming pools or spas. CF series filters
utilize multiple reusable, reinforced polyester filter
cartridge elements to provide a high degree of water
clarity and long filter cycles with minimum care.