Herunterladen Inhalt Inhalt Diese Seite drucken

behnke AT2 Anleitung Seite 45

Aufzugnotrutelefon
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

*51*
"Record announce-
ment" #
*52*
"Record announce-
ment" #
*61*
0 or 1 #
only #
*62*
0 or 1 #
only #
*73*
1 – 3 #
*74*
0 or 1 #
*89*
0 or 1 #
Voice recordings
This announcement is played in the cabin after the
emergency call is triggered. The recording is made via
the internal microphone of the elevator emergency
telephone.
This announcement is played to the recipient of the
emergency call after the call is accepted and played in
the cabin.
0 = deactivate announcement recorded in configuration
step 51
1 = activate announcement recorded in configuration
step 51
only # = play announcement recorded in configuration
step 51
0 = deactivate announcement recorded in configuration
step 52
1 = activate announcement recorded in configuration
step 52
only # = play announcement recorded in configuration
step 52
Optional connections
Additional input function. Defines what happens to the
alarm input if the filter is activated.
0 = none (deactivation, factory default)
1 = filter (the emergency call triggering is blocked if the
filter is activated)
2 = LMS, sends a monitoring alarm upon input activation
3 = reset/maintenance
Additional input switch/filter as normally open or nor-
mally closed contact:
0 = switch contact = normally open contact (NO) (default)
1 = switch contact = normally closed contact (NC)
Emergency call button in the cabin:
0 = Emergency call button = normally open contact (NO)
(default)
1 = Emergency call button = normally closed contact (NC)
Behnke AT2 Manual