configurAtion StepS

8. CONFIGURATION STEPS

8.1. Local configuration on the device using an internal keyboard:

1. Start configuration:
2. Enter security code: *
3. Configure the device according to the configuration table (cf. the following table)
4. Exit set-up mode: *

8.2. Remote configuration via an MFW dial-up phone:

1. Call the elevator emergency phone, wait until the emergency phone accepts the call
2. Start configuration:
3. Enter security code: *
4. Configure the device according to the configuration table (cf. the following table)
5. Exit set-up mode: *
*11*
#
*12*
#
#
*13*
*14*
#
*72*
01 to 99 #
0 or 1 #
*75*
42
# (0000 default security code)
* #
# (0000 default security code)
* #
Emergency call settings
Phone number of the alarm receiver (1-16 digits). When
operating on an analogue telephone extension, a delay
between 0 (outside line) and external phone number can
be set by adding asterisks (*). Each asterisk corresponds
to one second of delay at the corresponding position.
Example for outside line access with "0":
*11*0**1234567#
To delete phone numbers, call up the configuration step
and confirm with # (do not enter any digits).
For example: *11*#.
The four phone numbers configured here are dialled
a maximum of 3 times in the specified sequence
(11,12,13,14). When a call is answered and confirmed, the
call cycle is interrupted.
Number of dial tones before dialling the next phone
number (default = 08). Redial function, 12 call cycles
max.
When an emergency call is triggered, the elevator
telephone establishes a direct connection to a specified
recipient without dialling a telephone number for this
purpose. Feature of the telephone system
0 = normal telephone line (default)
1 = hotline